H07Z-R 450/750 V
Used for AC voltage up to 1000 volts or DC voltage up to 750 volts, the internal wiring of the switchboard and switchboard, generally installed in the pipeline, for the internal wiring of equipment with a working temperature of 90°C, suitable for public places (such as government buildings, etc.) where smoke and poisonous gas may cause life threats and damage to equipment. The cable does not produce corrosive gases when burned, which is especially important for electrical equipment.
apply
Used for AC voltage up to 1000 volts or DC voltage up to 750 volts, the internal wiring of the switchboard and switchboard, generally installed in the pipeline, for the internal wiring of equipment with a working temperature of 90°C, suitable for public places (such as government buildings, etc.) where smoke and poisonous gas may cause life threats and damage to equipment. The cable does not produce corrosive gases when burned, which is especially important for electrical equipment.
peculiarity
- BS 7211
- IEC 60754-2,
- EN 50267
- VDE 0482-267
ADDITIONAL INFORMATION
- Customizable colors
Product structure
conductor | Multi-strand bare copper conductors, according to IEC 60228 Cl-2 (H05Z-R) |
---|---|
insulation | Cross-linked polyolefin EI5 insulation |
Core color | The color coding of the wire core follows VDE-0293 |
Technical parameters
Operating voltage | 450 / 750V |
---|---|
Test voltage | 2500 V |
Bending radius | Dynamic bend radius: 15 x Ø
– Static bending radius: 10 x Ø |
Temperature range | Flexible application: +5/+90°C
short circuit high temperature; 250°C |
Insulation resistance | 10 MΩ x km |
Fire resistance | Flame retardant in accordance with IEC 60332.1 standard |
Oil resistance | Meets internal standards |
Implementation standards | HD 22.9 S2, VDE-0282 Part 9, BS 7211, IEC 60754-2, EN 50267, VDE 0482-267, CE Low Voltage 73/23/EEC and 93/68/EEC Directives, ROHS Certification |
environmental protection | Comply with EU RoHS directive |