FROR16 O.R. UNEL 300/500 V

Cables for fixed installations comply with the requirements of the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.
Multi-core cables for energy, control, signal, command or measurement systems with oil-resistant outer jackets.
The non-propagating of fire (low-risk beam mounting) and small exterior dimensions make it particularly suitable for walkie-talkie, civil, industrial indoor and on-board machine applications.
The cable can always be installed in coexistence with 450/750V energy cables, in addition, it can also coexist with 0/0kV energy cables to power loads with a nominal voltage of 230/400V if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current).

application

Cables for fixed installations comply with the requirements of the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.
Multi-core cables for energy, control, signal, command or measurement systems with oil-resistant outer jackets.
The non-propagating of fire (low-risk beam mounting) and small exterior dimensions make it particularly suitable for walkie-talkie, civil, industrial indoor and on-board machine applications.
The cable can always be installed in coexistence with 450/750V energy cables, in addition, it can also coexist with 0/0kV energy cables to power loads with a nominal voltage of 230/400V if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current).
All this does not rule out possible problems due to possible electromagnetic interference.
It can also be used for stress-free occasional mobile apps.

Underground installations (even if protected) and permanent outdoor installations (even if protected) are not allowed.

peculiarity

 

  • CEI 20-29 IEC 60228
  • CEI 20-11
  • CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
  • CEI UNEL 36762
  • CEI EN 60811-404

ADDITIONAL INFORMATION

  • Customizable core/sheath color

Product structure

conductor Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards
insulation PVC mixed material, R2 grade
color CEI UNEL 00722 – 00725 (for HD 308 S2 – EN50334)
structure Concentric layer stranded/bundle stranded conductors
Wrap the bag not
shield not
Sheath material: PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404
Sheath color Grey (based on RAL 7035 colour card)

Technical parameters

 

Operating voltage Section ≤ 0.75 mm²: 300/500V

Section ≥ 1.00 mm²: 450/750V

Test voltage Section ≤ 0.75 mm²: 2000V

Section ≥ 1.00 mm²: 2500V

Temperature range Minimum operating temperature

• Fixed laying: -25°C

• Non-stressed temporary mobile laying: -5°C

Maximum operating temperature

• Fixed laying: +70°C

• Non-stressed temporary mobile laying: +70°C

Short-circuit maximum temperature

+160°C

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.