FROR16 O.R. PE 300/500 V
Fixed laying cables in accordance with the EU Building Products Regulation (CPR EU 305/11) are flame retardant and low smoke for the following scenarios:
Multi-core control cable: used for signal transmission, control loops and measurement systems, equipped with oil-resistant reinforced outer sheath (insulation class 0.6/1kV).
application
-
- Fixed laying cables in accordance with the EU Building Products Regulation (CPR EU 305/11) are flame retardant and low smoke for the following scenarios:
Multi-core control cable: used for signal transmission, control loops and measurement systems, equipped with oil-resistant reinforced outer sheath (insulation class 0.6/1kV).
Low smoke halogen-free characteristics (low fire risk when laid in bundles), compact structure, especially suitable for:
- Building intercom system
- Civil and industrial indoor wiring
- Device internal connection
Expanded Applications:
Since the jacket has a reinforced insulation rating of 0.6/1kV, the cable is also suitable for:
- Cable pipes are directly buried and laid
- Pipelines are laid on the periphery of the plant
At the same time, it supports temporary mobile laying without stress (such as short-term wiring needs in acidic environments).
- Fixed laying cables in accordance with the EU Building Products Regulation (CPR EU 305/11) are flame retardant and low smoke for the following scenarios:
peculiarity
- CEI 20-29/IEC 60228 (Conductor Standard)
- CEI 20-11 (Cable Structure Standard)
- CEI EN 60332-3-24 Cat.C/IEC 60332-3-24 Cat.C (Bundle Combustion Test Class C)
- CEI EN 60811-404 (Oil Resistance Test)
Scope of application:
Fixed laying cable in accordance with EU CPR 305/11 regulations, with flame retardant and smoke suppression properties (S2, D0, A3 class), oil-resistant reinforced sheath (0.6/1kV insulation class).
Typical applications: building intercom systems, industrial control loops (PLC/DCS), internal wiring of equipment
New permitted scenarios: direct burial of cable pipelines and laying of pipelines on the periphery of the plant
Laying restrictions: It is forbidden to bury directly without protection, and it is forbidden to lay permanent outdoor exposure
ADDITIONAL INFORMATION
- 可定制芯/护套颜色
Product structure
conductor | Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards |
---|---|
insulation | PVC mixed material, R2 grade |
color | Conductor colour scale: DIN 47100 standard |
structure | Concentric layer stranded structure |
Wrap the bag | not |
shield | not |
Sheath material: | PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404 |
Sheath color | Outer sheath colour: RAL 5015 blue (original document corrected to blue) |
Technical parameters
Operating voltage | Conductor working voltage: 300/500V
Outer sheath withstand voltage class: 0.6/1kV (reinforced thickness) |
---|---|
Test voltage | Power Frequency Withstand Voltage Value: 2000V (AC RMS) |
Temperature range | Fixed laying minimum temperature -25°C maximum temperature +70°C
Non-stressed temporary mobile laying minimum temperature -5°C maximum temperature +70°C Instantaneous maximum temperature: +160°C (duration≤5s) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |