YSLY-OB/-JB/-OZ/-JZ Cca 450/750 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables are suitable for power transmission, control, signaling, measurement or command while maintaining small size and excellent flexibility. It is used in industry for machine wiring, conveyor systems, production lines, as well as ventilation and heating systems, industrial equipment and power stations. Suitable for installation in normal or wet environments, for fixed or limited dynamic installations without mechanical stress (non-continuous movement).
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables are suitable for power transmission, control, signaling, measurement or command while maintaining small size and excellent flexibility. It is used in industry for machine wiring, conveyor systems, production lines, as well as ventilation and heating systems, industrial equipment and power stations. Suitable for installation in normal or wet environments, for fixed or limited dynamic installations without mechanical stress (non-continuous movement).
300/500V and 450/750V (section ≤ 6.00 mm²): Underground installation is not allowed, even if protected.
0.6/1kV (section ≥ 10.00 mm²): Direct or indirect underground installation (in the presence of water conditions AD7).
peculiarity
-
- IEC 60228
- IEC 60332-3-24 Class C
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards |
---|---|
insulation | Flame retardant PVC composite |
color | HD 308 S2 Standard (-OB/-JB)
Black with numbered (-JZ) or yellow-green (-OZ) |
structure | Concentric layers are twisted |
Wrap the bag | / |
shield | / |
Sheath material: | Flame retardant PVC composite |
Sheath color | Grey (RAL 7001 standard colour) |
Technical parameters
Operating voltage | Conductor operating voltage
Section≤ 2.5mm²: 300/500V Cross-section=4.00 and 6.00mm²: 450/750V Section≥ 10.00mm²: 0.6/1kV Outer sheath working voltage Section≤ 2.5mm²: 300/500V Cross-section=4.00 and 6.00mm²: 450/750V Section≥ 10.00mm²: 0.6/1kV |
---|---|
Test voltage | Section≤ 2.5mm²: 2000V
Cross-section = 4.00 and 6.00 mm²: 2500 V Section≥ 10.00mm²: 4000V |
Temperature Style | Minimum operating temperature fixed installation: -25°C
Occasional stress-free mobile installation: -5°C Maximum operating temperature fixed installation: +70°C Occasional stress-free mobile installation: +70°C Maximum short-circuit temperature: +160° Celsius |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |