YSLCY-OB/-JB/-OZ/-JZ Dca 450/750 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables are suitable for power transmission, control, signaling, measurement or command while maintaining small size and excellent flexibility. Used in industry for machine wiring, conveyor systems, production lines as well as ventilation and heating systems, industrial equipment and power stations. Suitable for installation in normal or humid environments, for fixed or limited dynamic installations without mechanical stress (discontinuous motion).
Shielding helps prevent electromagnetic interference.
application
-
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables are suitable for power transmission, control, signaling, measurement or command while maintaining small size and excellent flexibility. Used in industry for machine wiring, conveyor systems, production lines as well as ventilation and heating systems, industrial equipment and power stations. Suitable for installation in normal or humid environments, for fixed or limited dynamic installations without mechanical stress (discontinuous motion).
Shielding helps prevent electromagnetic interference.
300/500V and 450/750V (section ≤ 6.00 mm²): Underground installation is not allowed, even if protected.
0.6/1kV (section ≥ 10.00 mm²): Underground installation is allowed. Direct or indirect (presence of water condition AD7).
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
peculiarity
-
- IEC 60228
- IEC 60332-3-24 Class C
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards |
---|---|
insulation | Flame retardant PVC composite (tested by IEC 60332-1) |
color | HD 308 S2 Standard Color (-OB/-JB Code)
Black with numbered (-JZ) or yellow-green (-OZ) |
structure | Concentric stranding (HD 21.3 compliant) |
Wrap the bag | Integral polyester strap wrap |
shield | Integral tinned copper braided shielding (coverage ≥85%) |
Sheath material: | Flame retardant PVC composite material (oxygen index ≥30%) |
Sheath color | Light grey (RAL 7001 standard colour, ΔE≤3) |
Technical parameters
Operating voltage | Conductor operating voltage
Section≤ 2.5mm²: 300/500V Section 4.00/6.00mm²: 450/750V Section≥ 10.00mm²: 0.6/1kV Outer sheath working voltage Section≤ 2.5mm²: 300/500V Section 4.00/6.00mm²: 450/750V Section≥ 10.00mm²: 0.6/1kV |
---|---|
Test voltage | Section≤ 2.5mm²: 2000V (AC, 5min)
Section 4.00/6.00mm²: 2500V (AC, 5min) Section≥ 10.00mm²: 4000V (AC, 5min) |
Temperature range | Fixed laying: -25°C ~ +70°C
Non-stressed temporary mobile laying: -5°C ~ +70°C Short-circuit ultimate temperature: +160°C (duration ≤5 seconds, IEC 60949 compliant) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |