YSLY -OB/-JB/-OZ/-JZ Dca 450/750 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables are suitable for power transmission, control, signaling, measurement or command while maintaining small size and excellent flexibility. It is used in industry for machine wiring, conveyor systems, production lines, as well as ventilation and heating systems, industrial equipment and power stations. Suitable for installation in normal or wet environments, for fixed or limited dynamic installations without mechanical stress (non-continuous movement).
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables are suitable for power transmission, control, signaling, measurement or command while maintaining small size and excellent flexibility. It is used in industry for machine wiring, conveyor systems, production lines, as well as ventilation and heating systems, industrial equipment and power stations. Suitable for installation in normal or wet environments, for fixed or limited dynamic installations without mechanical stress (non-continuous movement).
300/500V and 450/750V (section ≤ 2.5 mm²): Underground installation is not allowed, even if protected.
0.6/1kV (section ≥ 10.00 mm²): Direct or indirect underground installation (presence of water condition AD7).
peculiarity
-
- /
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5) |
---|---|
insulation | Flame retardant PVC composite |
color | HD 308 S2(-OB/-JB) |
structure | Concentric layer stranded structure |
Wrap the bag | / |
shield | / |
Sheath material: | Flame retardant PVC composite |
Sheath color | RAL 7001 grey |
Technical parameters
Operating voltage | Core operating voltage
300/500V cross-section≤ 2.5mm² 450/750V cross-section = 4.00 and 6.00 mm² 0.6/1kV section ≥ 10.00 mm² Outer sheath working voltage 300/500V cross-section≤ 2.5mm² 450/750V cross-section = 4.00 and 6.00 mm² 0.6/1kV section ≥ 10.00 mm² |
---|---|
Test voltage |
|
Temperature range | Operating temperature range
▸ Fixed laying: -25°C ~ -5°C ▸ Non-stressed temporary mobile laying: +70°C ~ +70°C Short-circuit tolerance limit ▸ Maximum instantaneous temperature: +160°C (duration ≤5 seconds) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |