2XSLCY-J MOTOR 3+3PE Cca 450/750 V

The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.

Shielded cables are used to power motors with frequency converters when full electromagnetic compatibility (EMC) is required due to their special construction.

The symmetrical cable structure (3 + 3PE) ensures the symmetry of the supply voltage on the motor terminals. Suitable for static and dynamic connections (occasional movements) in industrial plants, process lines and machinery operating in dry environments.

The cable must be protected from water and moisture.

application

The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.

Shielded cables are used to power motors with frequency converters when full electromagnetic compatibility (EMC) is required due to their special construction.

The symmetrical cable structure (3 + 3PE) ensures the symmetry of the supply voltage on the motor terminals. Suitable for static and dynamic connections (occasional movements) in industrial plants, process lines and machinery operating in dry environments.

The cable must be protected from water and moisture.

Even if protected, it is not allowed to lay underground.

peculiarity

    • IEC 60228

    ADDITIONAL INFORMATION

    • Custom core/jacket color

Product structure

conductor Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5)
insulation Cross-linked polyethylene (XLPE) insulation
color Brown + black + gray + yellow and green two-color x3
structure Concentric layer stranded conductors
Wrap the bag Full-section polyester strap
shield First shield:

Aluminum-plastic composite tape (fully wrapped)

Second shield:

Tinned copper braided mesh (coverage ≥85%)

Sheath material: Flame retardant PVC composite sheath
Sheath color RAL 9005 Pure Black

Technical parameters

 

Operating voltage Core operating voltage 0.6/1 kV

The outer jacket operates at 1.8kV DC and 1.2kV AC

Test voltage 4000V
Temperature range Operating temperature range

▸ Fixed laying: -25°C ~ -5°C

▸ Non-stressed temporary mobile laying: +90°C ~ +90°C

Short-circuit tolerance limit

▸ Maximum instantaneous temperature: +250°C (duration ≤5 seconds)

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.