2XSLCY-J MOTOR 4G Eca 450/750 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Shielded cables for powering motors with frequency converters when full electromagnetic compatibility (EMC) is required.
Suitable for static and dynamic connections (occasional movements) in industrial plants, process lines and machinery operating in dry environments.
application
-
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Shielded cables for powering motors with frequency converters when full electromagnetic compatibility (EMC) is required.
Suitable for static and dynamic connections (occasional movements) in industrial plants, process lines and machinery operating in dry environments.
The cable must be protected from water and moisture.
Even if protected, underground installation outdoors is not allowed.
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
peculiarity
-
- IEC 60228
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5) |
---|---|
insulation | Cross-linked polyethylene (XLPE) |
color | Brown + black + gray + yellow and green |
structure | Concentric layer stranded conductors |
Wrap the bag | Full-section polyester strap |
shield | First shield:
Full-section aluminum-plastic composite belt Second shield: Full section tinned copper woven mesh |
Sheath material: | Flame retardant PVC composite sheath |
Sheath color | transparent |
Technical parameters
Operating voltage | Core operating voltage 0.6/1 kV
The outer jacket operates at 1.8kV DC and 1.2kV AC |
---|---|
Test voltage | 4000V |
Temperature range | Operating temperature range
▸ Fixed laying: -25°C ~ -5°C ▸ Non-stressed temporary mobile laying: +90°C ~ +90°C Short-circuit tolerance limit ▸ Maximum instantaneous temperature: +250°C (duration ≤5 seconds) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |