Application
FEP thermocouple cable. This cable can be used as a thermocouple extension cable and compensation cable for various types of thermocouples, such as Type J, Type K, Type T, Type S, Type N, Type R/S.
A 18 L (1,5 mm²) · A 18-022 L (0,22 mm²)
Very effective against fats, oils, salts and acids
DIN 43710 / 43714 (not for type B*)
* Non-standardized compensation cable for type B thermocouples with application temperatures up to 100 °C or 200 °C.
C= Compensating cable · X = Extension cable
Additional information
Construction
|
FEP
|
|
|
|
|
| 2 core |
FEP
|
|
|
| Structure |
|
| Wrap |
A 18 L: 1,5 mm²
A 18-022 L: 0,22 mm²
|
|
Insulation
Shape
|
| Outer diameter |
Round
A 18-022 L: about 1,0 kg Foil
|
Technical data
| Bending radius |
12xd
|
| Radiation resistance |
1 x 10^7 cJ/kg
|
| Insulation temperature range |
Fixed installation: -90/+180°C
Flexible application: -55/+180°C
|
| Insulation resistance |
> 1 M Ω x km
|
| Fire resistance |
Conforms to IEC 60332-3-24 + VDE 0482-332-3-24 Standard, no flame spread
IEC 60332-3-25 + VDE 0482-332-3-25 Cat. C or D, see Chapter N “Technical Data”.
Flame retardant and self-extinguishing properties comply with IEC 60332-1-2 + VDE 0482-332-1-2 standards.
|
| Chemical resistance |
Very effective against fats, oils, salts and acids
|
| Environmentally friendly |
CompliantEURoHS Directive
|
Dimensions
| No. |
Model |
Standard |
Type |
Material |
Cable type |
Insulation color (sheath) |
Voltage at 100 °C |
|
| L04338958 |
A 18 L |
IEC 60584 |
Type T |
Cu – CuNi |
TX |
brown/white (brown) |
4,28 mV |
|
| L04338952 |
A 18 L |
IEC 60584 |
Type J |
Fe – CuNi |
JX |
black/white (black) |
5,27 mV |
|
| L04338995 |
A 18 L |
IEC 60584 |
Type K |
NiCr – Ni |
KCA |
green/white (green) |
4,10 mV |
|
| L04338999 |
A 18 L |
IEC 60584 |
Type K |
NiCr – Ni |
KCB |
green/white (green) |
4,10 mV |
|
| L04338954 |
A 18 L |
IEC 60584 |
Type K |
NiCr – Ni |
KX |
green/white (green) |
4,10 mV |
|
| L04338953 |
A 18 L |
IEC 60584 |
Type E |
NiCr – CuNi |
EX |
purple/white (purple) |
6,32 mV |
|
| L04338997 |
A 18 L |
IEC 60584 |
Type R/S |
PtRh13 – PTPtRh10 – PT |
R/SCB |
orange/white (orange) |
0,65 mV |
|
| L04338991 |
A 18 L |
IEC 60584 |
Type N |
NiCrSi – NiSi |
NC |
pink/white (pink) |
2,77 mV |
|
| L04338992 |
A 18 L |
DIN 43710 / 43714 |
Type L |
Fe CuNi |
LX |
red/blue (blue) |
5,37 mV |
|
| L04338994 |
A 18-022 L |
DIN 43710 / 43715 |
Type K |
─ |
KCA |
─ |
4,10 mV |
|
| L04338996 |
A 18-022 L |
DIN 43710 / 43716 |
Type R/S |
─ |
R/SCB |
─ |
0,65 mV |
|
| L04338998 |
A 18 L |
DIN 43710 / 43717 |
Type U |
Cu – CuNi |
UX |
red/brown (brown) |
4,25 mV |
|
| L04338901 |
A 18-022 L |
DIN 43710 / 43718 |
Type B* |
─ |
BC-100 |
─ |
0,00 mV |
|
| L04338902 |
A 18-022 L |
DIN 43710 / 43719 |
Type B* |
─ |
BC-200 |
─ |
0,033 mV |
|
| L04331958 |
A 18-022 L |
IEC 60584 |
Type T |
Cu – CuNi |
TX |
brown/white (brown) |
4,28 mV |
|
| L04331952 |
A 18-022 L |
IEC 60584 |
Type J |
Fe – CuNi |
JX |
black/white (black) |
5,27 mV |
|
| L04331995 |
A 18-022 L |
IEC 60584 |
Type K |
NiCr – Ni |
KCA |
green/white (green) |
4,10 mV |
|
| L04331999 |
A 18-022 L |
IEC 60584 |
Type K |
NiCr – Ni |
KCB |
green/white (green) |
4,10 mV |
|
| L04331954 |
A 18-022 L |
IEC 60584 |
Type K |
NiCr – Ni |
KX |
green/white (green) |
4,10 mV |
|
| L04331953 |
A 18-022 L |
IEC 60584 |
Type E |
NiCr – CuNi |
EX |
purple/white (purple) |
6,32 mV |
|
| L04331997 |
A 18-022 L |
IEC 60584 |
Type R/S |
PtRh13 – PTPtRh10 – PT |
R/SCB |
orange/white (orange) |
0,65 mV |
|
| L04331991 |
A 18-022 L |
IEC 60584 |
Type N |
NiCrSi – NiSi |
NC |
pink/white (pink) |
2,77 mV |
|
| L04331992 |
A 18-022 L |
DIN 43710 / 43714 |
Type L |
Fe CuNi |
LX |
red/blue (blue) |
5,37 mV |
|
| L04331998 |
A 18-022 L |
DIN 43710 / 43717 |
Type U |
Cu – CuNi |
UX |
red/brown (brown) |
4,25 mV |
|
Other sizes and colors are available upon request.