FG16H2R16 Cca 300/500 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Single-core cables are suitable for energy transmission and signal and command transmission when electromagnetic interference is required in industrial and residential buildings.
Suitable for indoor fixed installations, even wet, as well as outdoor walkways, pipes, pathways, or similar facilities.
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Single-core cables are suitable for energy transmission and signal and command transmission when electromagnetic interference is required in industrial and residential buildings.
Suitable for indoor fixed installations, even wet, as well as outdoor walkways, pipes, pathways, or similar facilities.
Allows for direct or indirect underground installation.
peculiarity
- CEI 20-29 IEC 60228
- CEI 20-11
- CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
- CEI 20-13 P.Q.A.
HEPR rubber insulation (G16 class) with temperature resistance range from -15°C to +90°C
The PVC outer sheath (R16 class) has passed the oil resistance test according to CEI EN 60811-404
Fully shielded construction ensures electromagnetic compatibility (according to EN 50288)
ADDITIONAL INFORMATION
- Customizable core/sheath color
Product structure
conductor | Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards |
---|---|
insulation | HEPR Rubber Compound (G16 Grade) |
color | Conductor colour scale: DIN 47100 standard |
structure | Fully covered polyester strap |
Wrap the bag | not |
shield | Full coverage copper braided mesh (coverage ≥85%) |
Sheath material: | PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404 |
Sheath color | Outer sheath colour: RAL 7035 standard grey |
Technical parameters
Operating voltage | Conductor voltage rating 0.6/1kV IEC 60502-1
Sheath withstand voltage class 0.6/1kV EN 50618 |
---|---|
Test voltage | Power frequency withstand voltage test 4000V/5min IEC 60332-1 |
Temperature range | Minimum operating temperature -15°C long-term operation allowance
Maximum operating temperature +90°C long-term operation allowance Short-circuit withstand temperature +250°C for a duration of ≤5 seconds |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |