FG16OHH2R16 300/500 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Three-core cable with concentric shielding for power transmission and signal transmission.
It is especially used to power motors controlled by inverters/frequency converters, as well as to connect inverters to meters in factories.
Suitable for indoor fixed installations, including wet fixed installations, as well as outdoor walkways, pipes, channels, or similar facilities.
application
-
-
-
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Three-core cable with concentric shielding for power transmission and signal transmission.
It is especially used to power motors controlled by inverters/frequency converters, as well as to connect inverters to meters in factories.
Suitable for indoor fixed installations, including wet fixed installations, as well as outdoor walkways, pipes, channels, or similar facilities.
Allows for direct or indirect underground installation.
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
peculiarity
- CEI 20-29 IEC 60228
- CEI 20-11
- CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
- CEI 20-13 P.Q.A.
Electromagnetic shielding performance: Concentric shielding structure effectively suppresses high-frequency interference (according to EN 50288-7)
Environmental Adaptability:
Operating temperature range: -15°C to +90°C
Oil resistance: Tested according to CEI EN 60811-404
ADDITIONAL INFORMATION
- Customizable core/sheath color
Product structure
conductor Three-core symmetrical structure insulation HEPR rubber-based compound, G16 mass color Conductor colour scale: DIN 47100 standard structure Concentric layer stranded structure Wrap the bag Full section polyester strap wrapping shield The first shield is aluminum-plastic composite belt (fully covered) with a thickness of ≥0.1mm Second shield Tinned copper braided mesh (coverage ≥85%)
Cross-sectional area requirements:
• ≤16mm²: equal to the cross-sectional area of the phase line
• ≥ 25mm²: ≥16mm² or 50% of the phase cross-sectional area
Sheath material: PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404 Sheath color RAL 7035 standard grey Technical parameters
Operating voltage The core operating voltage is 0.6/1kV The working voltage of the outer sheath is 0.6/1kV
Test voltage Test voltage 4000V Temperature range Operating temperature range: -15°C to +90°C Oil resistance: Tested according to CEI EN 60811-404
environmental protection Comply with EU RoHS directive -
-
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |