FG16OR16AR16 300/500 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Single-core armored cable for signaling and control, insulated with high modulus EPDM rubber.
Suitable for indoor installation, even in wet environments, and outdoors. Ideal for fixing on masonry and metal structures or hanging installations.
application
-
-
-
-
-
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Single-core armored cable for signaling and control, insulated with high modulus EPDM rubber.
Suitable for indoor installation, even in wet environments, and outdoors. Ideal for fixing on masonry and metal structures or hanging installations.Galvanized steel braided reinforcements provide exceptional mechanical protection and strength, making them particularly suitable for industrial environments with high operating conditions.
Allows for direct or indirect underground installation.
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
peculiarity
- CEI 20-29 IEC 60228
- CEI 20-11
- CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
- CEI 20-13 P.Q.A.
ADDITIONAL INFORMATION
- Customizable core/sheath color
Product structure
conductor Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards insulation HEPR Rubber Compound (G16 Grade) color Conductor colour scale: DIN 47100 standard structure Concentric layer stranded structure Wrap the bag Full section polyester belt wrap (thickness ≥ 0.05mm) shield Galvanized steel wire braided armour≥ 90% (according to IEC 60288) Sheath material: PVC mixed material, R16 grade, thickness ≥ 1.2mm, oil resistance according to CEI EN 60811-404 Sheath color Outer sheath colour: RAL 7035 standard grey Technical parameters
Operating voltage The core operating voltage is 0.6/1kV The working electricity of the outer sheath is 0.6/1kV
Test voltage 4000V Temperature range Minimum operating temperature -15°C long-term operation allowance Maximum operating temperature +90°C long-term operation allowance
Short-circuit withstand temperature +250°C for a duration of ≤5 seconds
environmental protection Comply with EU RoHS directive -
-
-
-
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |