FG16R16AR16Cca 300/500 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Single-core armored cable for signaling and control, insulated with high modulus EPDM rubber.
Suitable for indoor installation, even in wet environments, and outdoors. Ideal for fixing on masonry and metal structures or hanging installations.
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Single-core armored cable for signaling and control, insulated with high modulus EPDM rubber.
Suitable for indoor installation, even in wet environments, and outdoors. Ideal for fixing on masonry and metal structures or hanging installations.
The galvanized steel braided armor makes it recommended for DC circuits and provides exceptional mechanical protection and robustness, especially for applications in industrial environments with high service requirements.
Allows for direct or indirect underground installation.
peculiarity
- CEI 20-29 IEC 60228
- CEI 20-11
- CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
- CEI 20-13 P.Q.A.
ADDITIONAL INFORMATION
- Customizable core/sheath color
Product structure
conductor | Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards |
---|---|
insulation | HEPR Rubber Compound (G16 Grade) |
color | Conductor colour scale: DIN 47100 standard |
structure | Concentric layer stranded structure |
Wrap the bag | Full section polyester strap wrapping |
shield | Full section galvanized steel wire braided (coverage ≥90%) |
Sheath material: | PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404 |
Sheath color | Outer sheath colour: RAL 7035 standard grey |
Technical parameters
Operating voltage | The core operating voltage is 0.6/1kV
The working electricity of the outer sheath is 0.6/1kV |
---|---|
Test voltage | 4000V |
Temperature range | Minimum operating temperature -15°C long-term operation allowance
Maximum operating temperature +90°C long-term operation allowance Short-circuit withstand temperature +250°C for a duration of ≤5 seconds |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |