FROR16 O.R. DIN 300/500 V

Fixed laying cables that comply with the requirements of the EU Construction Products Regulation (CPR EU 305/11) with flame retardant and smoke suppression properties.

Multi-core control cables for signal transmission, control loops and measurement systems, equipped with oil-resistant outer sheaths. Its low-smoke halogen-free characteristics (low fire risk when laid in bundles) and compact construction make it particularly suitable for building intercom systems, civil/industrial indoor wiring and internal connections of equipment.

It can coexist with 450/750V power cables. When used for power supply in Class 0 systems (AC rated voltage ≤50V or DC/ripple-free voltage ≤120V), it can also coexist and lay with 0.6/1kV (230/400V rated voltage) power cables. However, it is necessary to pay attention to possible electromagnetic interference problems.

application

Fixed laying cables that comply with the requirements of the EU Construction Products Regulation (CPR EU 305/11) with flame retardant and smoke suppression properties.

Multi-core control cables for signal transmission, control loops and measurement systems, equipped with oil-resistant outer sheaths. Its low-smoke halogen-free characteristics (low fire risk when laid in bundles) and compact construction make it particularly suitable for building intercom systems, civil/industrial indoor wiring and internal connections of equipment.

It can coexist with 450/750V power cables. When used for power supply in Class 0 systems (AC rated voltage ≤50V or DC/ripple-free voltage ≤120V), it can also coexist and lay with 0.6/1kV (230/400V rated voltage) power cables. However, it is necessary to pay attention to possible electromagnetic interference problems.

Allowed for non-stressed temporary mobile laying scenarios.

It is strictly forbidden to lay directly buried (including protection) and permanent outdoor laying (including protection).

peculiarity

  • CEI 20-29/IEC 60228
  • CEI 20-11
  • CEI EN 60332-3-24 Cat.C/IEC 60332-3-24 Cat.C
  • CEI UNEL 36762
  • CEI EN 60811-404

ADDITIONAL INFORMATION

  • Customizable core/sheath color

Product structure

conductor Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards
insulation PVC mixed material, R2 grade
color CEI UNEL 00722 – 00725 (for HD 308 S2 – EN50334)
structure Concentric layer stranded structure
Wrap the bag not
shield not
Sheath material: PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404
Sheath color RAL 7035 grey

Technical parameters

 

Operating voltage ≤0.75mm² cross-section: 300/500V

≥ 1.00 mm² cross-section: 450/750 V

Test voltage ≤0.75mm² cross-section: 2000V

≥ 1.00mm² cross-section: 2500V

Temperature range Fixed laying: -25°C to +70°C

Non-stressed temporary mobile laying: -5°C to +70°C

Short-circuit tolerance temperature

+160°C (max)

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.