FROR16 O.R. PE 300/500 V

Fixed laying cables in accordance with the EU Building Products Regulation (CPR EU 305/11) are flame retardant and low smoke for the following scenarios:

Multi-core control cable: used for signal transmission, control loops and measurement systems, equipped with oil-resistant reinforced outer sheath (insulation class 0.6/1kV).

application

    • Fixed laying cables in accordance with the EU Building Products Regulation (CPR EU 305/11) are flame retardant and low smoke for the following scenarios:

      Multi-core control cable: used for signal transmission, control loops and measurement systems, equipped with oil-resistant reinforced outer sheath (insulation class 0.6/1kV).

      Low smoke halogen-free characteristics (low fire risk when laid in bundles), compact structure, especially suitable for:

      • Building intercom system
      • Civil and industrial indoor wiring
      • Device internal connection

      Expanded Applications:

      Since the jacket has a reinforced insulation rating of 0.6/1kV, the cable is also suitable for:

      • Cable pipes are directly buried and laid
      • Pipelines are laid on the periphery of the plant

      At the same time, it supports temporary mobile laying without stress (such as short-term wiring needs in acidic environments).

peculiarity

 

  • CEI 20-29/IEC 60228 (Conductor Standard)
  • CEI 20-11 (Cable Structure Standard)
  • CEI EN 60332-3-24 Cat.C/IEC 60332-3-24 Cat.C (Bundle Combustion Test Class C)
  • CEI EN 60811-404 (Oil Resistance Test)

Scope of application:

Fixed laying cable in accordance with EU CPR 305/11 regulations, with flame retardant and smoke suppression properties (S2, D0, A3 class), oil-resistant reinforced sheath (0.6/1kV insulation class).

Typical applications: building intercom systems, industrial control loops (PLC/DCS), internal wiring of equipment

New permitted scenarios: direct burial of cable pipelines and laying of pipelines on the periphery of the plant

Laying restrictions: It is forbidden to bury directly without protection, and it is forbidden to lay permanent outdoor exposure

ADDITIONAL INFORMATION

  • 可定制芯/护套颜色

Product structure

conductor Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards
insulation PVC mixed material, R2 grade
color Conductor colour scale: DIN 47100 standard
structure Concentric layer stranded structure
Wrap the bag not
shield not
Sheath material: PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404
Sheath color Outer sheath colour: RAL 5015 blue (original document corrected to blue)

Technical parameters

 

Operating voltage Conductor working voltage: 300/500V

Outer sheath withstand voltage class: 0.6/1kV (reinforced thickness)

Test voltage Power Frequency Withstand Voltage Value: 2000V (AC RMS)
Temperature range Fixed laying minimum temperature -25°C maximum temperature +70°C

Non-stressed temporary mobile laying minimum temperature -5°C maximum temperature +70°C

Instantaneous maximum temperature: +160°C (duration≤5s)

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.