Cables for fixed installations comply with the requirements of the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.
Multi-core cables for energy, control, signal, command or measurement systems with oil-resistant outer jackets.
The non-propagating of fire (low-risk beam mounting) and small exterior dimensions make it particularly suitable for walkie-talkie, civil, industrial indoor and on-board machine applications.
The cable can always be installed in coexistence with 450/750V energy cables, in addition, it can also coexist with 0/0kV energy cables to power loads with a nominal voltage of 230/400V if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current).
application
Cables for fixed installations comply with the requirements of the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.
Multi-core cables for energy, control, signal, command or measurement systems with oil-resistant outer jackets.
The non-propagating of fire (low-risk beam mounting) and small exterior dimensions make it particularly suitable for walkie-talkie, civil, industrial indoor and on-board machine applications.
The cable can always be installed in coexistence with 450/750V energy cables, in addition, it can also coexist with 0/0kV energy cables to power loads with a nominal voltage of 230/400V if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current).
All this does not rule out possible problems due to possible electromagnetic interference.
It can also be used for stress-free occasional mobile apps.
Underground installations (even if protected) and permanent outdoor installations (even if protected) are not allowed.
peculiarity
- CEI 20-29 IEC 60228
- CEI 20-11
- CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
- CEI UNEL 36762
- CEI EN 60811-404
ADDITIONAL INFORMATION
- Customizable core/sheath color
Product structure
conductor | Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards |
---|---|
insulation | PVC mixed material, R2 grade |
color | CEI UNEL 00722 – 00725 (for HD 308 S2 – EN50334) |
structure | Concentric layer stranded/bundle stranded conductors |
Wrap the bag | not |
shield | not |
Sheath material: | PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404 |
Sheath color | Grey (based on RAL 7035 colour card) |
Technical parameters
Operating voltage | Section ≤ 0.75 mm²: 300/500V
Section ≥ 1.00 mm²: 450/750V |
---|---|
Test voltage | Section ≤ 0.75 mm²: 2000V
Section ≥ 1.00 mm²: 2500V |
Temperature range | Minimum operating temperature
• Fixed laying: -25°C • Non-stressed temporary mobile laying: -5°C Maximum operating temperature • Fixed laying: +70°C • Non-stressed temporary mobile laying: +70°C Short-circuit maximum temperature +160°C |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |