​FS18O(H)H2R18 300/500 V with shielding

Suitable for internal installation in dry or wet places for fixed installation. FS18OR18 Cables are suitable for general applications in buildings that meet the requirements of fire response; For bundled installations with higher risk of fire in the event of fire, with fire response classes CCA-S3, D1, A3. Not suitable for underground installation. Suitable for outdoor intermittent or temporary use.

application

Suitable for internal installation in dry or wet places for fixed installation. FS18OR18 Cables are suitable for general applications in buildings that meet the requirements of fire response; For bundled installations with higher risk of fire in the event of fire, with fire response classes CCA-S3, D1, A3. Not suitable for underground installation. Suitable for outdoor intermittent or temporary use.

Certifications and standards

 

  • CEI 20-22/2 , CEI 20-34, CEI 20-37, CEI 20-20/1/2, EN 50265, HD 21.5 Sez. 3, IEC 60332-3– CEI-UNEL 35716; – CEI EN/IEC 60228; – CEI EN/IEC 60332-1-2;  – CEI EN 50267-2-1; – CPR EN 50399 – CEI EN 50525-1 p.q.a./a.p.;  – CEI EN 50525-2-31 p.q.a./ a.p.; – CEI EN 60754-2; EN 61034-2; – EN 50575:2014+A1:2016; – CEI 64-8:V4.
  • Low Voltage DC 2006/95/EC,
  • ROHS DC 2002/95/EC certification

ADDITIONAL INFORMATION

 

 

  • Can be customized Core Count X1.5mm² + Core Count X 0.34mm²
  • For example: 4*1.5mm²+4X0.34mm²
  • Custom splices, wiring harnesses, etc

Product structure

conductor Bare copper conductors – in accordance with DIN VDE 0295 cl.6, BS 6360 cl.5 and IEC 60228 cl.6
insulation PVC type S18 with low corrosive gas emissions
color Color coded to HD-308/EN50334, yellow-green ground wire (3-core and above)
shield Aluminum/polyester tape, annealed pure copper braid
Sheath material: PVC type R18 for reduced halogen emissions
Sheath color Black (RAL 9005), other colours available

Technical parameters

Nominal voltage 300/500 V
Test voltage Core/Core 1200/2000
Bending radius Fixed laying: 4xd

Flexible application: 10 xd

Flame retardant IEC 60332.1
Temperature range Fixed laying: -15/+70°C

Flexible application: +0/+70°C

Insulation resistance 20 MΩ x km
environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification Insulation thickness Outer diameter – ø Cable weight ≈ Max. Resistance (20° C)
L02516007 2 x 0,5  mm² 0,4 mm 6.8 mm 47 kg/km 39 kg/km Send an inquiry
L02510310 2 x 0,75 mm² 0,4 mm 7.2 mm 58 kg/km 26 kg/km Send an inquiry
L02510410 2 x 1,0 mm² 0,4 mm 7.5 mm 66 kg/km 19.5 kg/km Send an inquiry
L02510510 2 x 1,5 mm² 0,4 mm 8.4 mm 88 kg/km 13.3 kg/km Send an inquiry
L02510710 2 x 2,5 mm² 0,5 mm 10.1 mm 131 kg/km 7.98 kg/km Send an inquiry
L02511210 3 x 0,5 mm² 0,4 mm 7.2 mm 58 kg/km 39 kg/km Send an inquiry
L02511810 3 x 0,75 mm² 0,4 mm 7.5 mm 71 kg/km 26 kg/km Send an inquiry
L02512510 3 x 1,0 mm² 0,4 mm 7.9 mm 83 kg/km 19.5 kg/km Send an inquiry
L02513210 3 x 1,5 mm² 0,4 mm 8.8 mm 112 kg/km 13.3 kg/km Send an inquiry
L02513410 3 x 2,5 mm² 0,5 mm 9.5 mm 170 kg/km 7.98 kg/km Send an inquiry
L02514210 4 x 0,5 mm² 0,4 mm 7.7 mm 65 kg/km 39 kg/km Send an inquiry
L02515010 4 x 0,75  mm² 0,4 mm 8.3 mm 84 kg/km 26 kg/km Send an inquiry
L02516010 4 x 1,0 mm² 0,4 mm 8.8 mm 98 kg/km 19.5 kg/km Send an inquiry
L02510315 4 x 1,5 mm² 0,4 mm 9.5 mm 128 kg/km 13.3 kg/km Send an inquiry
L02510415 4 x  2,5 mm² 0,5 mm 11.5 mm 196 kg/km 7.98 kg/km Send an inquiry
L02510515 5 x 0,5 mm² 0,4 mm 8.3 mm 78 kg/km 39 kg/km Send an inquiry
L02510715 5 x 0,75 mm² 0,4 mm 9.0 mm 102 kg/km 26 kg/km Send an inquiry
L02511215 5 x 1,0 mm² 0,4 mm 9.4 mm 121 kg/km 19.5 kg/km Send an inquiry
L02511815 5 x 1,5 mm² 0,4 mm 10.5 mm 164 kg/km 13.3 kg/km Send an inquiry
L02512515 5 x 2,5 mm² 0,5 mm 12.7 mm 250 kg/km 7.98 kg/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.