FTG18OM16AM16 300/500 V

The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke. Multi-core galvanized steel braided
LSZH cable for energy, signaling and control, insulated with halogen-free flame retardant elastic compound, flexible conductors protected by flame retardant barriers.
It is suitable for power supply to emergency users in places where there is a risk of explosion or fire (emergency exits and lighting, alarm signals, smoke or gas signals, escalators, fire pumps, fire curtains, etc.).

application

The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke. Multi-core galvanized steel braided
LSZH cable for energy, signaling and control, insulated with halogen-free flame retardant elastic compound, flexible conductors protected by flame retardant barriers.
It is suitable for power supply to emergency users in places where there is a risk of explosion or fire (emergency exits and lighting, alarm signals, smoke or gas signals, escalators, fire pumps, fire curtains, etc.).
If the cable is stored/laid outdoors, it must be protected from UV exposure. Allows direct or indirect underground installation.

peculiarity

 

  • CEI 20-29 IEC 60228 standard
  • CEI 20-11
  • CEI EN 60332-3-24 Cat.C IEC 60332-3-24 Cat.C CEI 20-45 P.Q.A.
  • UNI 9795


– For Øest. ≤ 20mm: CEI EN 50200 EN 50200 (Duration test 120 minutes.) PH120)

– For Øest. >20mm: CEI EN IEC 60331-1 (Duration test 120 minutes. F120)

ADDITIONAL INFORMATION

  • Customizable core/sheath color

Product structure

conductor Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards
insulation Mica/fiberglass composite tape (according to IEC 60331 fire resistance standard)
color CEI UNEL 00722 (HD 308 S2 compliant)
structure Concentric stranded structure ≤ 16 times the cable diameter
Wrap the bag Cladding: Full section polyester band

Thickness: 0.05±0.01mm

shield Galvanized steel wire braided armor
Sheath material: M16 Low Smoke Halogen-Free Thermoplastic Material (LSZH-TP)
Sheath color RAL 5015 Standard Blue (Chromatic Aberration ΔE≤1.5)

Technical parameters

 

Operating voltage 600/1000V
Test voltage 600/1000V
Temperature range Minimum operating temperature -25°C long-term operation allowance

Maximum operating temperature +90°C long-term operation allowance

Short-circuit withstand temperature +250°C for a duration of ≤5 seconds

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.