H05BQ-F Fca 450/750 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Flexible cable for heavy mobile service that can be installed in dry or wet places as well as outdoors.
It can be used for connections that withstand moderate mechanical stress, such as power tools, motors, or machines that can be transported on construction sites or in agricultural applications.
Suitable for refrigeration and heating equipment applications, as long as they do not come into contact with hot parts and are not exposed to thermal radiation.
It is particularly suitable for situations where cables are subjected to high wear and tear stress. It can also
be used for fixed installation.
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Telephone arrangement braid for extensions.
Suitable for applications not covered by CPR regulations and installations in enclosed environments, except in cases where there is a specific risk of fire ignition/spread, cables with excellent fire response performance (at least CCA-S3, D1, A3) are recommended.
Even if it is protected, it is not allowed to lay underground.
peculiarity
- CEI 20-29 IEC 60
-
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Flexible cable for heavy mobile service that can be installed in dry or wet places as well as outdoors.
It can be used for connections that withstand moderate mechanical stress, such as power tools, motors, or machines that can be transported on construction sites or in agricultural applications.
Suitable for refrigeration and heating equipment applications, as long as they do not come into contact with hot parts and are not exposed to thermal radiation.
It is particularly suitable for situations where cables are subjected to high wear and tear stress. It can also
be used for fixed installation.
Even if protected, it is not allowed to lay underground.
- The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
peculiarity
-
- IEC 60228
- EN 50525-2-21
- EN 50363
ADDITIONAL INFORMATION
Black, yellow or gray- The structure/section does not meet the requirements of the 50525-2-21 standard
Product structure
conductor Rigid tinned copper conductor Ø0.60mm insulation PVC-based mixture color Compliant with CEI UNEL 00724 structure Concentric layers are twisted Wrap the bag / shield / Sheath material: / Sheath color / Technical parameters
Operating voltage The core working voltage is 300/500V The outer sheath works with electricity 300/500V
Test voltage 2000V Temperature range Minimum operating temperature -50°C Maximum operating temperature +90°C
Short-circuit tolerance temperature +250°C (max)
environmental protection Comply with EU RoHS directive -
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |