H05V2-R PVC insulation Class II conductor -30 ∽+90°C 300/500V
The H05V2-R is mainly installed inside the equipment and is used in lighting, dry rooms, production facilities, switches and switchboards under protected conditions.
application
The H05V2-R is mainly installed inside the equipment and is used in lighting, dry rooms, production facilities, switches and switchboards under protected conditions.
peculiarity
- HD 21.3 S3, VDE-0281 Part 3, CEI 20-20, CEI20-52,
- CE Low Voltage 73/23/EEC and 93/68/EEC Directive, ROHS certified
ADDITIONAL INFORMATION
- Customizable colors
- Higher temperatures can be customized
Product structure
conductor | Tinned copper/bare copper according to IEC 60228, VDE 0295, Level 2 |
---|---|
insulation | PVC, TI1 complies with EN 50363-3 + VDE 0207-363-3 |
Insulation color | Black, red, blue, yellow, brown, orange, etc |
Technical parameters
Operating voltage | Uo/U 300/500 V |
---|---|
Test voltage | 2000 V |
Bending radius | 10 x d |
Temperature range | Fixed laying: -5/+80°C
Flexible application: -30/+90°C |
Flame retardant | IEC 60332.1 conforms to EN50525-2-31 (EC 60227-3) |
Insulation resistance | 10 MΩ x km |
Fire resistance | Flame retardant and self-extinguishing according to IEC 60332-1-2 + VDE 0482-332-1-2 |
Oil resistance | Meets internal standards |
Chemical resistance | See “Technical Data” – Chemical Resistance |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | Copper wire diameter -ø | Finished product diameter – ø | Copper weight | Cable weight ≈ | |
---|---|---|---|---|---|---|
L01970050 | 0,50 mm² | 0,80 mm | 2,4 mm | 4.9 kg/km | 10 kg/km | Send an inquiry |
L01970075 | 0,75 mm² | 0,97 mm | 2,6 mm | 7,6 kg/km | 13 kg/km | Send an inquiry |
L01971000 | 1,00 mm² | 1,13 mm | 2,8 mm | 9,2 kg/km | 15 kg/km | Send an inquiry |