H05V3V3H6-F PVC Sheathed Control Cable 300/ 500V -40°C Flat >2 Cores
H05V3V3H6-F flat cable is used in elevators or freight elevators, as well as in the fast running part of the machine, H05V3V3H6-F cable has no extension carrier and can be installed in elevators with a running speed of up to 4.0 m/s, with a free suspension height of up to 45 meters and a maximum height of 80 meters.
H05V3V3D3H6-F cable, if the running speed is between 4.0 m/s and 6.3 m/s, the cable extension carrier to be used, at this time, its free suspension height is up to 80 meters, and the transportation height limit is up to 150 meters.
application
H05V3V3H6-F flat cable is used in elevators or freight elevators, as well as in the fast running part of the machine, H05V3V3H6-F cable has no extension carrier and can be installed in elevators with a running speed of up to 4.0 m/s, with a free suspension height of up to 45 meters and a maximum height of 80 meters.
H05V3V3D3H6-F cable, if the running speed is between 4.0 m/s and 6.3 m/s, the cable extension carrier to be used, at this time, its free suspension height is up to 80 meters, and the transportation height limit is up to 150 meters.
CE= products comply with the EU Low Voltage Directive 2014/35/EU
certifications and standards
- EN 50214, HD 359 S3, IEC 60332-1, CSA C22.2 N° 49, DIN VDE 0281 Part 404, UL 62
- CE Low Voltage 73/23/EEC & 93/68/EEC Directive.,
- ROHS certified
Product structure
conductor | Soft bare copper conductors in accordance with DIN VDE 0295 cl.5, BS 6360 cl.5, IEC 60228 cl.5 and HD 383 |
---|---|
insulation | PVC insulation T15 follows VDE 0207 Part 4 |
Core color | Color coding according to VDE 0293-308, 6 cores and above: black core with white numerals, plus yellow-green ground wire |
shield | not |
Sheath material | PVC sheath TM2 complies with VDE 0207 Part 5 |
Sheath color | Black (RAL9005), other colors can be customized according to the request. |
Technical parameters
Nominal voltage | Uo/U 300/500 V |
---|---|
Test voltage | Core/Core 2000V |
Bending radius | Fixed laying: 4.0xD
Flexible application: 7.5xD |
Temperature range | Fixed laying: -40/+70 °C
Flexible application: – 35/+70 °C Temperature reachable in case of short circuit: +160º C |
Flame retardant | Meets VDE 0472 Part 804, IEC 60332-1B test |
Insulation resistance | 350 MΩ x km |
environmental protection | Comply with EU RoHS directive |
Cable parameters
Project number | specification | Conductor max. diameter | Outer Diameter – ø ± 5% | Copper weight | Cable weight | |
---|---|---|---|---|---|---|
H56075205 | 12 x 0,75 mm² | 0.21 mm | 33.7 x 4.3 mm | 79 Kg/km | 251 Kg/km | Send an inquiry |
H56075305 | 16 x 0,75 mm² | 0.21 mm | 44.5 x 4.3 mm | 105 Kg/km | 335 Kg/km | Send an inquiry |
H56075405 | 18 x 0,75 mm² | 0.21 mm | 49.2 x 4.3 mm | 118 Kg/km | 371 Kg/km | Send an inquiry |
H56075207 | 24 x 0,75 mm² | 0.21 mm | 65.7 x 4.3 mm | 157 Kg/km | 496 Kg/km | Send an inquiry |
H56100307 | 12 x 1mm² | 0.21 mm | 34.4 x 4.4 mm | 105 Kg/km | 285 Kg/km | Send an inquiry |
H56100407 | 20 x 1 mm² | 0.21 mm | 57 x 4.4 mm | 175 Kg/km | 472 Kg/km | Send an inquiry |
H56100507 | 24 x 1 mm² | 0.21 mm | 68 x 4.4 mm | 216 Kg/km | 565 Kg/km | Send an inquiry |