H07Z-U/H07Z-R Rubber E3 insulation Class 5 conductors -40 ∽+105°C 450/750V

Designed for internal wiring of switchboards and switchboards with AC nominal voltages up to 1000 volts or DC voltages up to 750 volts. Generally installed in the pipes or pipes and internal wiring of electrical appliances with a maximum operating temperature of 90 degrees Celsius, and generally installed in areas where fumes and toxic fumes may pose a threat to life and equipment (e.g. public and government buildings). Cables do not produce corrosive gases when burning, which is especially important when installing electronic devices.

 

 apply

Designed for internal wiring of switchboards and switchboards with AC nominal voltages up to 1000 volts or DC voltages up to 750 volts. Generally installed in the pipes or pipes and internal wiring of electrical appliances with a maximum operating temperature of 90 degrees Celsius, and generally installed in areas where fumes and toxic fumes may pose a threat to life and equipment (e.g. public and government buildings). Cables do not produce corrosive gases when burning, which is especially important when installing electronic devices.
 
CE= products comply with the EU Low Voltage Directive 2014/35/EU

peculiarity

  • Customized splices, wiring harnesses, etc. are available
  • Low smoke, halogen-free
  • HD 22.9 S2
  • VDE-0282 Part-9
  • BS 7211
  • IEC 60754-2
  • EN 50267
  • VDE 0482-267
  • CE Low Voltage
  • Directive 73/23/EEC and 93/68/EEC

Product structure

conductor Solid bare copper single wire bare copper stranded wire according to IEC 60228 Cl-1 (H05Z-U / H07Z-U) complies with IEC 60228 Cl-2 (H07Z-R) standard
insulation Cross-linked polyolefin EI5 core insulation
Color code The number of cores is in accordance with VDE-0293 color

Technical parameters

 

Nominal voltage 300/500V
Test voltage 2500 V
Bending radius/min Bending bend radius 15 x diameter

Static bend radius 10 x diameter

Temperature range Bending temperature +5 ºC to +90 ºC

Short-circuit temperature +250 ºC

Halogen-free Compliant with IEC 60754-1 + VDE 0482-754-1
Fire resistance Flame retardant in accordance with IEC 60332.1 standard
Insulation resistance 10 MΩ x km
environmental protection Comply with EU RoHS directive

 

Cable parameters

numbering specification Copper weight Finished product weight
K7100 .. 25* 0,5 mm² 4,8 Kg/Km 8 Kg/Km Send an inquiry
K7100 .. 34* 0,75 mm² 7,2 Kg/Km 12 Kg/Km Send an inquiry
K7100 .. 50* 1,0 mm² 9,6 Kg/Km 14 Kg/Km Send an inquiry

Other sizes and colors can be upon request. The above data is for reference and subject to reality.