LiHCH-TP-DIN B2ca 450/750 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multiple pairs of LSZH cable total shielding for data transmission in electronics and computers, for signaling, measurement, command or control systems, and in general applications where effective protection from external electromagnetic interference and small size are required.
It is especially suitable for places with fire risk and dense crowds, such as schools, offices, theaters, hospitals, etc.
Suitable for installation in normal or wet environments for fixed or limited dynamic installations (non-continuous motion) without mechanical stress.
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multiple pairs of LSZH cable total shielding for data transmission in electronics and computers, for signaling, measurement, command or control systems, and in general applications where effective protection from external electromagnetic interference and small size are required.
It is especially suitable for places with fire risk and dense crowds, such as schools, offices, theaters, hospitals, etc.
Suitable for installation in normal or wet environments for fixed or limited dynamic installations (non-continuous motion) without mechanical stress.
If the cable is stored outdoors, it must be protected from UV exposure. Even if it is protected, it is not allowed to lay underground.
peculiarity
-
- CEI 20-29 IEC 60228
- CEI 20-11
- CEI EN 60332-3-24 Car.C IEC 60332-3-24 Cat.C
- CEI UNEL 36762
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5) |
---|---|
insulation | LSZH thermoplastic composites |
color | DIN 47100 standard |
structure | Wire to twist
Concentric layer twisted into a cable |
Wrap the bag | Full-section polyester strap |
shield | Full section tinned copper woven mesh |
Sheath material: | LSZH thermoplastic composites |
Sheath color | RAL 7001 grey |
Technical parameters
Operating voltage | Core operating voltage
300V cross-section≤0.75 mm² 500V cross-section ≥1.00 mm² Outer sheath working voltage 450/750V |
---|---|
Test voltage |
|
Temperature range | Operating temperature range
▸ Fixed laying: -40°C ~ -5°C ▸ Non-stressed temporary mobile laying: +70°C ~ +70°C Short-circuit tolerance limit ▸ Maximum instantaneous temperature: +160°C (duration ≤5 seconds) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |