LiHH-DIN Cca 450/750 V
The cables meet the requirements in the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.
Multi-core LSZH cable for control, signaling, command and measurement systems with very low smoke and toxic gas emissions.
It is particularly suitable for places exposed to fire hazards and high population density, such as schools, offices, theaters, hospitals, etc.
Suitable for installation in dry or humid indoor environments, for static or limited dynamic installations without mechanical stress (non-permanent movement).
application
The cables meet the requirements in the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.
Multi-core LSZH cable for control, signaling, command and measurement systems with very low smoke and toxic gas emissions.
It is particularly suitable for places exposed to fire hazards and high population density, such as schools, offices, theaters, hospitals, etc.
Suitable for installation in dry or humid indoor environments, for static or limited dynamic installations without mechanical stress (non-permanent movement).
If stored outdoors, the cable must be protected from UV rays.
Even if protected, it is not allowed to lay underground.
peculiarity
-
- IEC 60228
- IEC 60332-3-24 Class C
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5) |
---|---|
insulation | LSZH thermoplastic composites, type TI6 |
color | Compliant with DIN 47100 full chromatography |
structure | Concentric layer stranded conductors |
Wrap the bag | / |
shield | / |
Sheath material: | LSZH thermoplastic composites, type TM7 |
Sheath color | RAL 7001 Grey (ΔE≤2.0) |
Technical parameters
Operating voltage | The core working voltage is 300/500V
Outer sheath working voltage 300/ 500V |
---|---|
Test voltage | 2000V |
Temperature range | Operating temperature range
▸ Fixed laying: -40°C ~ -5°C ▸ Non-stressed temporary mobile laying: +70°C ~ +70°C Short-circuit tolerance limit ▸ Maximum instantaneous temperature: +160°C (duration ≤5 seconds) |
environmental protection | Comply with EU RoHS directive |
Technical parameters
Operating voltage | Conductor:
≤0.75mm²:300/500V ≥1.00mm²:450/750V Outer sheath: 450/750V (full section) |
---|---|
Test voltage | ≤0.75mm²:2000V AC/5min
≥1.00mm²:2500V AC/5min |
Temperature range | Operating temperature range
▸ Fixed laying: -25°C ~ +70°C ▸ Non-stressed temporary mobile laying: -5°C ~ +70°C Short-circuit tolerance limit ▸ Maximum instantaneous temperature: +160°C (duration ≤5 seconds) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |