LiYCY-TP-DIN Dca 450/750 V

This cable complies with the requirements of the Construction Products Regulation (CPR EU 305/11) and is designed to limit the generation and spread of smoke in fires.

application

This cable complies with the requirements of the Construction Products Regulation (CPR EU 305/11) and is designed to limit the generation and spread of smoke in fires.

This multi-pair integral shielded cable is suitable for:

  • Data transmission of electronic devices and computer systems

  • Signal transmission, measurement and control systems

  • Occasions that need to effectively resist external electromagnetic interference and require compact structure

Suitable installation environment:
✓ Dry or wet indoor locations
✓ Static or limited dynamic installation (non-continuous movement)
✓ Mechanically stress-free environments

Strictly prohibited:
✖ Underground laying (even if protective measures are taken) Permanently
✖ moving Occasions
✖ Environments where mechanical stress exists

peculiarity

    • IEC 60228
    • IEC 60332-3-24 Cat.C

    ADDITIONAL INFORMATION

    • Custom core/jacket color

Product structure

conductor Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5)

Conductor resistance: ≤13.3Ω/km (20°C, 0.75mm²)

insulation Flame retardant PVC composite (tested by IEC 60332-1-2)

Insulation Thickness: 0.4mm (nominal) ±10%

color Compliant with DIN 47100 full chromatography
structure Twisted pair structure (pitch ratio ≤20×D)

Concentric layered stranding (fill coefficient≥0.7)

Wrap the bag Integral polyester strap wrap (thickness 0.08±0.01mm)

Overlap rate≥ 25%

shield Integral tinned copper braided shielding (coverage ≥85%)

Weaving angle: 45±5°

Sheath material: Flame retardant PVC sheath (oxygen index ≥32%)

The thinnest point of the sheath ≥ nominal value × 80%+0.1mm

Sheath color RAL 7001 Grey (ΔE≤3)

Technical parameters

 

Operating voltage Conductor:

≤0.75mm²:300/500V

≥1.00mm²:450/750V

Outer sheath: 450/750V (full section)

Test voltage ≤0.75mm²:2000V AC/5min

≥1.00mm²:2500V AC/5min

Temperature range Operating temperature range

▸ Fixed laying: -25°C ~ +70°C

▸ Non-stressed temporary mobile laying: -5°C ~ +70°C

Short-circuit tolerance limit

▸ Maximum instantaneous temperature: +160°C (duration ≤5 seconds)

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.