LiYCY-TP-DIN PRIME Cca 450/750 V

The cables meet the requirements in the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.

Multiple pairs of cables for data transmission in electronics and computers for signaling, measurement, command and control systems, and more generally for applications that require effective protection from external electromagnetic interference and compact size.

Suitable for installation in dry or humid indoor environments, for static or limited dynamic installations (non-permanent motion) without mechanical stress. Even if it is protected, it is not allowed to lay underground.

application

The cables meet the requirements in the Construction Products Regulation (CPR EU 305/11) and are designed to limit the generation and spread of fire and smoke.

Multiple pairs of cables for data transmission in electronics and computers for signaling, measurement, command and control systems, and more generally for applications that require effective protection from external electromagnetic interference and compact size.

Suitable for installation in dry or humid indoor environments, for static or limited dynamic installations (non-permanent motion) without mechanical stress. Even if it is protected, it is not allowed to lay underground.

peculiarity

    • IEC 60228
    • IEC 60332-3-24 Class C

    ADDITIONAL INFORMATION

    • Custom core/jacket color

Product structure

conductor Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5)

Minimum bending radius: 6× cable outer diameter

insulation Flame retardant PVC composite (tested by IEC 60332-1-2)
color Compliant with DIN 47100 full chromatography
structure Twisted in pairs IEC61156

Total stranded  Concentric layers HD 18

Wrap the bag /
shield Shielding Type: Tinned copper braid

Coverage: ≥85%

Resistivity: ≤25Ω/km

Sheath material: Flame retardant PVC compound

Thickness: ≥1.5mm (in accordance with IEC 60502-1)

Oxygen Index: ≥32%

Sheath color RAL 7001 Grey (ΔE≤2.0)

Technical parameters

 

Operating voltage The core working voltage is 300/500V

Outer sheath working voltage 300/

500V

Test voltage 2000V
Temperature range Operating temperature range

▸ Fixed laying: -25°C ~ +70°C

▸ Non-stressed temporary mobile laying: -5°C ~ +70°C

Short-circuit tolerance limit

▸ Maximum instantaneous temperature: +160°C (duration ≤5 seconds)

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.