LiYY-DIN Cca 450/750 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables for control, signaling, measuring or commanding with very low smoke and toxic gas emissions. It is commonly used in door assemblies, electronic control devices, office equipment, measuring equipment, and anywhere small cable diameters are required. It is lightweight and has excellent flexibility.
Suitable for installation in normal or wet environments for fixed or limited dynamic installations without mechanical stress (not continuous motion).
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Multi-core cables for control, signaling, measuring or commanding with very low smoke and toxic gas emissions. It is commonly used in door assemblies, electronic control devices, office equipment, measuring equipment, and anywhere small cable diameters are required. It is lightweight and has excellent flexibility.
Suitable for installation in normal or wet environments for fixed or limited dynamic installations without mechanical stress (not continuous motion).
Even if it is protected, it is not allowed to lay underground.
peculiarity
-
- IEC 60228
- IEC 60332-3-24 Class C
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards |
---|---|
insulation | Flame retardant PVC composites (oxygen index ≥30%) |
color | DIN 47100 compliant (full chromatography) |
structure | Concentric stranding (HD 21.3 S3 compliant) |
Wrap the bag | / |
shield | / |
Sheath material: | Flame retardant PVC composite (tested by IEC 60332-1) |
Sheath color | Light grey (RAL 7001 standard colour, ΔE≤3) |
Technical parameters
Operating voltage | Conductor operating voltage
Section≤ 0.75mm²: 300/500V Section≥ 1.00mm²: 450/750V Outer sheath working voltage 450/750V (for all sections) |
---|---|
Test voltage | Section≤ 0.75mm²: 2000V
Section≥ 1.00mm²: 2500V |
Temperature Style | Fixed laying conditions: -25°C ~ +70°C
Non-stressed temporary mobile laying: -5°C ~ +70°C Short-circuit limit temperature +160°C (maximum duration of 5 seconds, according to IEC 60949) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |