LiYY-DIN Dca 450/750 V

The cable complies with the requirements in the Building Products Regulation (CPR EU 305/11) and is designed to limit the generation and spread of fire and smoke.

Multi-core cables for control, signal, command, and measurement systems with reduced form factors and excellent flexibility.
They are commonly used in intercom systems, electronic control devices, office machines, measuring equipment, and wherever small diameter cables are generally required. It offers excellent flexibility and light weight.

Suitable for installation in dry or humid indoor environments, in static or limited dynamic installations (non-permanent motion) without mechanical stress.

application

The cable complies with the requirements in the Building Products Regulation (CPR EU 305/11) and is designed to limit the generation and spread of fire and smoke.

Multi-core cables for control, signal, command, and measurement systems with reduced form factors and excellent flexibility.
They are commonly used in intercom systems, electronic control devices, office machines, measuring equipment, and wherever small diameter cables are generally required. It offers excellent flexibility and light weight.

Suitable for installation in dry or humid indoor environments, in static or limited dynamic installations (non-permanent motion) without mechanical stress.

Even if protected, it is not allowed to lay underground.

peculiarity

    • IEC 60228
    • IEC 60332-3-24 Class C

    ADDITIONAL INFORMATION

    • Custom core/jacket color

Product structure

conductor Bare copper wire complies with IEC 60228, VDE 0295, class 5 standards
insulation Flame retardant PVC composite
color Complies with DIN 47100
structure Concentric layered twisting
Wrap the bag /
shield /
Sheath material: Flame retardant PVC composite
Sheath color Grey (RAL 7001 standard colour)

Technical parameters

 

Operating voltage The core working voltage is 300/500V

The working voltage of the outer sheath is 300/500V

Test voltage 2000V
Temperature Style Operating temperature range

• Fixed laying: -25°C ~+70°C

• Non-stressed temporary mobile laying: -5°C ~ +70°C

Short-circuit tolerance temperature

• Up to +160°C (duration ≤5s)

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.