ULX FRXOHR16 Cca 300/300 V
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Globally shielded multi-pair cables for electronic devices for transmitting data between central units and peripherals via RS232 ports, for interconnection between devices that require high-quality transmission signals.
Suitable for applications not covered by CPR regulations and for installations in enclosed environments, except in cases where there is a specific risk of fire ignition/spread, cables with excellent fire response performance (at least CCA-S3, D1, A3) are recommended.
The cable can always be installed in coexistence with a 450/750V energy cable where permitted, and, if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current), it can also coexist with a 0.6/1kV energy cable to power a load with a nominal voltage of 230/400V.
application
The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.
Globally shielded multi-pair cables for electronic devices for transmitting data between central units and peripherals via RS232 ports, for interconnection between devices that require high-quality transmission signals.
Suitable for applications not covered by CPR regulations and for installations in enclosed environments, except in cases where there is a specific risk of fire ignition/spread, cables with excellent fire response performance (at least CCA-S3, D1, A3) are recommended.
The cable can always be installed in coexistence with a 450/750V energy cable where permitted, and, if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current), it can also coexist with a 0.6/1kV energy cable to power a load with a nominal voltage of 230/400V.
Even if it is protected, it is not allowed to lay underground.
peculiarity
- CEI 20-29 IEC 60228
- CEI 20-11
- CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
- CEI UNEL 36762
ADDITIONAL INFORMATION
- Customizable core/sheath color
- Galvanized steel braided armour with 450/750V
- Outer sheath with insulation voltage – Outer sheath with 0.6/1kV voltage for outdoor installation or underground cable conduit
Product structure
conductor | Tinned soft copper wire complies with IEC 60228, VDE 0295, Class 5 |
---|---|
insulation | PVC-based mixture, R2 grade |
color | Complies with DIN 47100 |
structure | Twisted pair
Concentric layer stranded wire pairs |
Wrap the bag | Integral polyester strap covering |
shield | Integral aluminum/polyester shielding with tinned soft copper streamline |
Sheath material: | PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404 |
Sheath color | Outer sheath colour: RAL 7035 standard grey |
Technical parameters
Operating voltage | The core working voltage is 300/300V
The outer sheath works with electricity 450/750V |
---|---|
Test voltage | 1500V |
Temperature range | Minimum operating temperature -15°C
Maximum operating temperature +70°C Short-circuit withstand temperature +160°C |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |