ULX FRXOHR16 Cca 300/300 V

The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.

Globally shielded multi-pair cables for electronic devices for transmitting data between central units and peripherals via RS232 ports, for interconnection between devices that require high-quality transmission signals.

Suitable for applications not covered by CPR regulations and for installations in enclosed environments, except in cases where there is a specific risk of fire ignition/spread, cables with excellent fire response performance (at least CCA-S3, D1, A3) are recommended.

The cable can always be installed in coexistence with a 450/750V energy cable where permitted, and, if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current), it can also coexist with a 0.6/1kV energy cable to power a load with a nominal voltage of 230/400V.

application

The cable complies with the requirements of the Construction Products Regulation (EU CPR 305/11) and is designed to limit the generation and spread of fire and smoke.

Globally shielded multi-pair cables for electronic devices for transmitting data between central units and peripherals via RS232 ports, for interconnection between devices that require high-quality transmission signals.

Suitable for applications not covered by CPR regulations and for installations in enclosed environments, except in cases where there is a specific risk of fire ignition/spread, cables with excellent fire response performance (at least CCA-S3, D1, A3) are recommended.

The cable can always be installed in coexistence with a 450/750V energy cable where permitted, and, if used to power a Class 0 system (nominal voltage less than or equal to 50V, if AC, or 120V, if DC or non-corrugated current), it can also coexist with a 0.6/1kV energy cable to power a load with a nominal voltage of 230/400V.

Even if it is protected, it is not allowed to lay underground.

peculiarity

 

  • CEI 20-29 IEC 60228
  • CEI 20-11
  • CEI EN 60332-3-24 Class C IEC 60332-3-24 Class C
  • CEI UNEL 36762

ADDITIONAL INFORMATION

  • Customizable core/sheath color
  • Galvanized steel braided armour with 450/750V
  • Outer sheath with insulation voltage – Outer sheath with 0.6/1kV voltage for outdoor installation or underground cable conduit

Product structure

conductor Tinned soft copper wire complies with IEC 60228, VDE 0295, Class 5
insulation PVC-based mixture, R2 grade
color Complies with DIN 47100
structure Twisted pair

Concentric layer stranded wire pairs

Wrap the bag Integral polyester strap covering
shield Integral aluminum/polyester shielding with tinned soft copper streamline
Sheath material: PVC mixed material, R16 grade, oil resistance according to CEI EN 60811-404
Sheath color Outer sheath colour: RAL 7035 standard grey

Technical parameters

 

Operating voltage The core working voltage is 300/300V

The outer sheath works with electricity 450/750V

Test voltage 1500V
Temperature range Minimum operating temperature -15°C

Maximum operating temperature +70°C

Short-circuit withstand temperature +160°C

environmental protection Comply with EU RoHS directive

Cable parameters

numbering specification The finished outer diameter is -ø Max. Resistance (20° C)
LS2380205 2 x 0.35 mm² 1.8X3.7 mm 247.0 ohm/km Send an inquiry
LS2380305 2 x 0.5 mm² 2.1X4.2 mm 39.0 ohm/km Send an inquiry
LS2380405 2 x 0.75 mm² 2.3X4.6 mm 26.0 ohm/km Send an inquiry
LS2380505 2 x 1.0 mm² 2.4X4.8 mm 19.5 ohm/km Send an inquiry
LS2380705 2 x 1.5 mm² 2.9X5.8 mm 13.3 ohm/km Send an inquiry
LS2381205 2 x 2.5 mm² 3.3X6.6 mm 7.98 ohm/km Send an inquiry

Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product. Other sizes and colors are available upon request. The above data is for reference only and is subject to the actual product.