XSLCH-J MOTOR 3+3PE Cca 450/750 V
Electrical cables comply with the requirements of the Construction Products Regulation (EU CPR 305/11) and are designed to limit the generation and spread of fire and smoke.
Shielded LSZH cables are used to power motors with frequency converters when full electromagnetic compatibility (EMC) is required due to their special construction.
The symmetrical cable structure (3 + 3PE) ensures the symmetry of the supply voltage on the motor terminals.
The cable is made entirely of halogen-free materials and does not release harmful substances in the event of a fire.
Suitable for static and dynamic connections (occasional movement) in industrial plants, process lines and machinery operating in normal or humid environments.
If the cable is stored/laid outdoors, it must be protected from UV exposure.
Direct or indirect underground installation (presence of water condition AD7).
application
Electrical cables comply with the requirements of the Construction Products Regulation (EU CPR 305/11) and are designed to limit the generation and spread of fire and smoke.
Shielded LSZH cables are used to power motors with frequency converters when full electromagnetic compatibility (EMC) is required due to their special construction.
The symmetrical cable structure (3 + 3PE) ensures the symmetry of the supply voltage on the motor terminals.
The cable is made entirely of halogen-free materials and does not release harmful substances in the event of a fire.
Suitable for static and dynamic connections (occasional movement) in industrial plants, process lines and machinery operating in normal or humid environments.
If the cable is stored/laid outdoors, it must be protected from UV exposure.
Direct or indirect underground installation (presence of water condition AD7).
peculiarity
-
- IEC 60228
- IEC 60332-3-24 Class C
ADDITIONAL INFORMATION
- Custom core/jacket color
Product structure
conductor | Class 5 Bare Copper Soft Conductors (IEC 60228 Class 5) |
---|---|
insulation | Cross-linked LSZH rubber composites |
color | Brown + black + gray + yellow and green |
structure | Concentric layer stranded conductors |
Wrap the bag | Full-section polyester strap |
shield | First shield:
Full-section aluminum-plastic composite belt Second shield: Full section tinned copper woven mesh |
Sheath material: | LSZH thermoplastic composites |
Sheath color | RAL 9005 Pure Black |
Technical parameters
Operating voltage | Core operating voltage 0.6/1 kV
The outer jacket operates at 1.8kV DC and 1.2kV AC |
---|---|
Test voltage | 4000V |
Temperature range | Operating temperature range
▸ Fixed laying: -40°C ~ -5°C ▸ Non-stressed temporary mobile laying: +90°C ~ +90°C Short-circuit tolerance limit ▸ Maximum instantaneous temperature: +250°C (duration ≤5 seconds) |
environmental protection | Comply with EU RoHS directive |
Cable parameters
numbering | specification | The finished outer diameter is -ø | Max. Resistance (20° C) | |
---|---|---|---|---|
LS2380205 | 2 x 0.35 mm² | 1.8X3.7 mm | 247.0 ohm/km | Send an inquiry |
LS2380305 | 2 x 0.5 mm² | 2.1X4.2 mm | 39.0 ohm/km | Send an inquiry |
LS2380405 | 2 x 0.75 mm² | 2.3X4.6 mm | 26.0 ohm/km | Send an inquiry |
LS2380505 | 2 x 1.0 mm² | 2.4X4.8 mm | 19.5 ohm/km | Send an inquiry |
LS2380705 | 2 x 1.5 mm² | 2.9X5.8 mm | 13.3 ohm/km | Send an inquiry |
LS2381205 | 2 x 2.5 mm² | 3.3X6.6 mm | 7.98 ohm/km | Send an inquiry |